Major issue on this error, disable port immediately if getting below error.
2021/06/08-13:56:17, [AN-1003], 1281572, SLOT 6 | FID 128, WARNING, switchname1, Latency bottleneck at slot 9, port 11. 10.33 percent of last 300 seconds were affected. Avg. time b/w transmits 1.0000 us.
2021/07/20-21:06:38, [AN-1010], 11564, SLOT 5 | FID 128, WARNING, backboneswitch, Severe latency bottleneck detected at slot 1 port 23.
investigate:
2021/06/08-14:40:22, [AN-1010], 1124481, SLOT 6 | FID 128, WARNING, switchname1, Severe latency bottleneck detected at slot 10 port 0.
investigate:
2021/06/09-11:54:34, [AN-1004], 1124531, SLOT 6 | FID 128, WARNING, switchname1, Slot 9, port 22 is a congestion bottleneck. 54.33 percent of last 300 seconds were affected by this condition.
check above logs by below command :
errdump |grep -i latency
errdump |grep -i bottleneck
errdump |grep -i congestion
check error on ports:
porterrshow (check crc, disc c3 errors)
check port flapping :
fabriclog -s